Online UPS High Frequency 10kva

FOB Price: Get Latest Price
Model:Classic H online 10kva
Certification:CE
Capable:UL
Minimum Order:100PCS
Brief Description:Online High frequency UPS EA900 II 1KVA ~ 10KVA with internal battery. Pure sine wave,large LCD display.

Doreen Zhang

  • Product Details

Basic Specification

BATTERY QTY6PCS 12V/9AH for 3kva
Weight75KG
ProtectionOvercurrent
Output Voltage220VAC
PhaseSingle Phase
ApplicationComputer, Instrumentation, Medical, Military, Networking, Other, Security / Monitoring / Alarm, Telecommunications
TypeOn-line

Detail Description

 

Technical Specification:
Model
EA901II
EA902II
EA903 II
EA906II
EA9010 II
Capacity
1KVA
2KVA
3KVA
6KVA
10KVA
INPUT
Rated input voltage
220V
Rated input frequency
50Hz/60Hz (self-adaption )
Input voltage Range
110~300 VAC (Half load),140~300VAC (Full load)
Input frequency Range
45-55Hz +/-0.5%   50Hz
55-65Hz +/-0.5%   60Hz
Phase
single phase+N+GND
Power factor
≥0.98
≥0.99
Input current (liner full load)
4.0A
8.1A
12.1A
24.2A
40.4A
THD
﹤5%
ByPass voltage range
186VAC-252VAC
OUTPUT
Rated voltage
208VAC/220VAC/230VAC/240VAC can be set on LCD
Power factor
0.8
Voltage distortion
±2%
DC component voltage
≤200mv
Output current crest factor
3:1
Rated frequency
AC mode
same as input frequency
Battery mode
50/60±0.2Hz
Phase lock speed
≤1Hz/s
Wave distortion
100% linear load <3%;100%; nonlinear load <5%
Transfer time
From Mains mode to battery mode
0ms
From battery mode to Mains mode
0ms
From Mains mode to bypass mode
<4ms
From bypass mode to Mains mode
<4ms
From normal mode  to ECO mode
≤10ms
System Efficiency
Full load
≧90 %
≧92%
ECO mode
≧94%
Inverter overload capacity
105%~150% 30s transfer to bypass mode giving alarm;
>150% 300ms transfer to bypass mode giving alarm;
Battery
Battery type
Lead Acid maintenance free battery
DC voltage
24V DC
48V DC
72V DC
168V DC
168V DC
Inbuilt battery
7AH/12V
7AH/12V
7AH/12V
9AH/12V
9AH/12V
Battery quantity
2
4
6
14
14
Charge
Output voltage
27.5±0.4V
55±0.6V
82.5±0.9V
193.7±0.9V
193.7±0.9V
Charge method
Three-stage charging
Recharge time
90% capacity after 5hrs charging (standard model)
According to battery capacity(long time model)
Input voltage range
80VAC~300VAC
Charge current
Standard model:1A
Long time model: 6A
(can extend to 12A)
Protection
Over-temp protection
Fan testing protection
AC  L and N connect wrong protection
Output short circuit protection
Control
Silence; cold start; AC restart; Auto restart.
Communication
RS232, SNMP card , USB
Software function
Statue analyze: Switch on/off UPS system, Monitor UPS working state ,store history
Display
LCD/LED
System Operating Environment
Operating environment
Operation tem.
0 ~ 40 ℃
Store tem.
-25℃ ~ 55 ℃
Humidity
20 ~ 90%(non-condensing)
Altitude
0m<altitude <1500m, over 1500m,
used with power derated
Noise
<50db (1-3kva)
<55db(6-10kva)
Dimension(W*D*H)
357*144*215
439*190*341
439*190*341
514*262*455
(Long time model)
574*262*710
(Standard model)
Weight(Kg)
Long time model
6
12
12.5
42
Standard model
10
20
24
57
 

Additional Information

Payment TermsL/C, T/T
Minimum Order100PCS
Lead Time / Delivery Time20 Day(s)
Sample AvailableYES Ask For Sample
Delivery Detailsby sea
FOB PortShenzhen
Loading InfoFOB
Packing InfoCOLOR BOX
Target Market(s)Africa(except Middle East), Central & Southern Asia, Eastern Europe, Mainland China, Middle East, North America

Send your message to this manufacturer


3000